Aguato

    COD and BOD removal from ABS resin wastewater by equalization, flotation and activated sludge

    An in-plant treatment works at a petrochemical complex in northwest Iran that pretreats wastewater from a unit producing 35 000 tonnes a year of ABS resin, before it goes on to the complex's central treatment plant. The wastewater is strong and contains acrylonitrile, styrene and cyanide. The works was designed for an average flow of 800 m³/day, but during sampling it received about 469 m³/day.

    Treatment line

    1. 01Three screens
    2. 02Grit chamberOne chamber of 12 m³ with a design retention time of about 0.4 hours.
    3. 03Equalization basinOne aerated basin of 508 m³ with a design retention time of about 15 hours.
    4. 04Fine screen
    5. 05Dissolved air flotationOne 24 m³ unit with a design retention of half an hour, with chemical addition and full-flow pressurization.
    6. 06Extended aeration activated sludge reactorTwo aeration basins of 766 m³ with a design retention of 22.5 hours.
    7. 07ClarifierTwo clarifiers of 105 m³, with sludge returned to the aeration basins.

    What the source found

    The works removed about 80% of COD, 90% of BOD and 89% of suspended solids, but a large share of the COD and BOD removal happened before the bioreactor, probably because volatile compounds were stripped to the air, mostly from the equalization basin. The flotation unit removed solids poorly, so effluent suspended solids stayed above the design value, and the bioreactor ran with too little biomass and a short retention time. About 90% of the acrylonitrile and styrene was removed, much of it by evaporation rather than biodegradation.

    Four sampling runs in July, August and October 2014 with 12-hour composite samples at the inlet and outlet of each unit, combined with long-term plant records and a flow mass balance.

    Water in, water out

    ParameterSymbolUnitInletOutletRemoval
    Average flowm3/d469
    CODCODmg/L1,34526081%
    BOD5BOD5mg/L7837790%
    Total suspended solidsTSSmg/L6497489%
    pH6.37
    CyanideCN−ppb1052.797%
    Temperature˚C34.530.3
    Total Kjeldahl nitrogenTKNmg/L61
    Acrylonitrilemg/L3143190%
    Styrenemg/L1231290%
    Dissolved oxygenDOmg/l2.1

    Inlet: raw wastewater entering the plant. Outlet: treated effluent leaving the clarifiers. Means (with standard deviations) from four sampling runs in 2014. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.