    Ammonia removal from UASB-treated sewage in a polishing pond

    The municipal sewage works of Rio Formoso on the southern coast of Pernambuco, designed for a population of 15,830, with each stage sized for 3,456 m³ per day. Sewage passes through screening, a grit chamber, a Parshall flume and three parallel UASB reactors before the pond studied here; after the pond the water goes through four percolating stone filters and is pumped to the river.

    Treatment line

    1. 01Polishing pond15,300 m² pond, 1.5 m deep, 28,050 m³, with about 8 days of retention. It is deeper than a usual polishing pond and has the configuration of a facultative pond.

    What the source found

    The pond removed on average 49% of ammonia nitrogen, with only small shares explained by ammonia volatilisation and uptake by algal biomass, and removal differed little between wet and dry seasons. Suspended solids fell by about 13% from inlet to outlet, while solids inside the pond rose as biomass grew, and phosphorus barely changed. The pond effluent met the national discharge requirements except for thermotolerant coliforms, which stayed above the legal requirement in every campaign.

    Samples at the pond inlet (combined UASB effluent), at three points on the surface and bottom of the pond, and at the pond outlet, taken around midday in 22 campaigns between September 2011 and November 2012, including two 24-hour campaigns in the wet and dry seasons.

    Water in, water out

    ParameterSymbolUnitInletOutletRemoval
    Total ammoniacal nitrogenNH3-Nmg/L34.517.649%
    Total Kjeldahl nitrogenTKNmg/L38.922.941%
    Total dissolved nitrogenTDNmg/L28.613.453%
    Total particulate nitrogenmg/L9.191.1%
    Organic nitrogenmg/L4.45.20%
    NitriteNO2−mg/L0.060.090%
    NitrateNO3−mg/L0.020.020%
    Total alkalinityAlkmg CaCO3/L234.2171
    Total suspended solidsTSSmg/L796913%
    Fixed suspended solidsFSSmg/L231535%
    Volatile suspended solidsVSSmg/L56640%
    Total phosphorusTPmg/L3.13
    Thermotolerant coliformsFC95%
    Total CODCODmg/L1871890%
    Dissolved CODsCODmg/L1228134%
    Particulate CODmg/L731100%
    Total BODBODmg/L48.654.10%
    Dissolved BODsBODmg/L41.611.173%
    Particulate BODmg/L12430%
    TurbidityUN6989.10%
    Chlorophyll aµg/L55
    Dissolved oxygenDOmg/L1.35
    Temperature°C28.829.8
    pH6.97.5

    Inlet: pond inlet, the combined UASB effluent. Outlet: polishing pond outlet. Arithmetic means over 22 campaigns from September 2011 to November 2012. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair. A parameter at 0% did not fall between the inlet and the outlet.