COD and nitrogen removal from sewage by an intermittently aerated membrane bioreactor
A 120 L pilot membrane bioreactor treating real domestic sewage, run for 60 days to test whether nitrification and denitrification can take place together in a single reactor. It was seeded with sludge from another activated sludge pilot treating the same sewage.
Treatment line
- 01BioreactorIntermittent aeration by a solenoid valve keeps oxygen low, sodium hydroxide is dosed to keep the liquid near neutral, and the hydraulic retention time is 6.5 hours.
- 02Membrane tankFlat-sheet ultrafiltration cassette of 6.25 m² with pores below 0.1 µm, run 9 minutes filtering to 1 minute relaxing, with sludge returned to the bioreactor by air lift.
What the source found
During start-up the unit removed 95% of COD and BOD and 91% of ammonium nitrogen, while total phosphorus fell by only a third, as expected without chemical dosing. Once simultaneous nitrification and denitrification began after about 35 days, total nitrogen removal rose, but organic carbon removal dropped, which is linked to soluble microbial products. Membrane fouling remained a challenge, with chemical cleaning needed whenever pressure passed 0.3 bar.
Weekly samples of feed and permeate; the removal figures are means for the first 35 days of start-up, before the switch to simultaneous nitrification and denitrification, and organic carbon is a mean over the whole run.
Water in, water out
| Parameter | Symbol | Unit | Inlet | Outlet | Removal |
|---|---|---|---|---|---|
| COD | COD | mg O2/L | 625 | 30 | 95% |
| BOD5 | BOD5 | mg O2/L | 260 | 13 | 95% |
| Ammonia nitrogen | NH3-N | mg N/L | 54 | 5 | 91% |
| Total Kjeldahl nitrogen | TKN | mg N/L | 85 | 16 | 81% |
| Total phosphorus | TP | mg P/L | 6 | 4 | 33% |
| Total organic carbon | TOC | mg L-1 | 61 | 15 | 75% |
| Turbidity | UNT | 0.4 |
Inlet: feed to the membrane bioreactor. Outlet: membrane permeate. Means of weekly samples over the first 35 days of start-up; organic carbon and turbidity are means over the whole monitoring period. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.