COD removal from domestic sewage by UASB reactors and anoxic and aerated tanks with biodiscs
A full-scale municipal works in Natal that treats only domestic sewage from about 250,000 inhabitants. Two of three planned modules are built and run as parallel lines, and during the study the works received an average of 32,669 m³/day. The secondary treatment described here follows a shared preliminary treatment and is followed by ultraviolet disinfection.
Treatment line
- 01UASB reactorsFour reactors per line receiving three quarters of the sewage; the other quarter bypasses them to feed the next stage, and excess sludge from the activated sludge stage is digested in them.
- 02Anoxic chamberOne pre-denitrification chamber per line, with an average retention time of 26 minutes.
- 03Aerated reactor with rotating biodiscsOne per line, combining suspended sludge with biofilm on 16 rotating biodiscs, with an average retention time of 39 minutes.
- 04Secondary clarifierOne per line.
What the source found
Total COD fell by 84% between the raw sewage and the treated effluent. The UASB reactors gave no net total COD removal because excess sludge sent to them for digestion was not being withdrawn and washed out with their effluent. Nitrification in the activated sludge stage was unsatisfactory.
Weekly composite samples, taken every four hours over 24 hours, of the raw sewage after preliminary treatment, after each stage and of the treated effluent over 167 days between August 2018 and January 2019.
Water in, water out
| Parameter | Symbol | Unit | Inlet | Outlet | Removal |
|---|---|---|---|---|---|
| COD | COD | mg/L | 593 | 94 | 84% |
| Soluble COD | sCOD | mg/L | 40 | 94% | |
| Total Kjeldahl nitrogen | TKN | mgN/L | 59 | ||
| Ammonium nitrogen | NH4-N | mgN/L | 33 | ||
| Volatile suspended solids | VSS | mg/L | 40 |
Inlet: raw sewage after preliminary treatment (UASB inlet). Outlet: treated effluent of the activated sludge stage. Means of weekly composite samples over 167 days between August 2018 and January 2019 (15 samples for COD, 11 for nitrogen). Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.