Aguato

    BOD and ammonia removal from sewage by UASB reactors and activated sludge with biodiscs

    A municipal sewage works in Natal, Rio Grande do Norte, treating domestic sewage from about twenty city districts in two parallel lines, each of which is one of three planned modules; the sewage first passes coarse screens, fine screens and grit chambers. The two built lines can take an average of 1,620 m³/h, and during the study the works received an average of 908 m³/h. Excess sludge from the secondary clarifiers is digested in the UASB reactors, the sludge treatment line had not yet started, and the ultraviolet disinfection channel was out of service.

    Treatment line

    1. 01UASB reactorsEight reactors in parallel, four per line, each of 1,420 m³, receiving three quarters of the degritted sewage.
    2. 02Anoxic chambersTwo mixed chambers of 1,298 m³ each that receive the UASB effluent, one quarter of the degritted raw sewage as a carbon source for denitrification, recycled aeration tank liquor and return sludge.
    3. 03Aeration tanks with biodiscsTwo aerated tanks, each with 16 rotating biodiscs of corrugated tubing that carry a biofilm, aerated and turned by blowers.
    4. 04Secondary clarifiersTwo circular clarifiers, 32 m in diameter and 3.5 m deep, with sludge and scum scrapers.

    What the source found

    BOD removal averaged 87%, below the design target, even though the works was running well under its design flow. Ammonia removal was high at 76%, but very little nitrate formed in the aeration tanks, so the removal was not by nitrification and denitrification; aeration problems were the likely cause. Suspended solids removal was unstable and well below the design target, as sludge built up in the UASB reactors and left with their effluent, and the two lines performed alike except for dissolved oxygen.

    Weekly flow-weighted composite samples, taken every four hours over the day, at the grit chamber outlet, after each stage and at the treated effluent from June to October 2012, with the inflow logged every 30 seconds; the figures shown compare the grit chamber outlet with the treated effluent.

    Water in, water out

    ParameterSymbolUnitInletOutletRemoval
    Temperature°C28.3128.69
    pH7.146.96
    Dissolved oxygenDOmg/L5.9
    BODBODmg/L3104187%
    Total suspended solidsTSSmg/L19094
    Volatile suspended solidsVSSmg/L1388439%
    Organic nitrogenmg/L3.63.52.8%
    Ammonium nitrogenNH4-Nmg/L29.87.376%
    Total Kjeldahl nitrogenTKNmg/L34.610.271%
    Nitrate nitrogenNO3-Nmg/L0.72.50%
    AlkalinityAlkmg CaCO3/L181.396.9

    Inlet: degritted sewage at the grit chamber outlet. Outlet: treated effluent after the secondary clarifiers. Means of weekly flow-weighted composite samples from June to October 2012. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair. A parameter at 0% did not fall between the inlet and the outlet.