Aguato

    Ammonia and nitrate removal from landfill leachate by ammonia stripping and activated sludge

    Raw leachate was collected at the municipal waste treatment centre of Londrina, Paraná, in operation since 2010; the leachate was at an intermediate stage of biological stabilisation. A single 14 m³ load was taken to a university laboratory and stored in a closed 15 m³ tank, then treated in a 2 m³ pilot installation run in sequential batches. The treated leachate was then used for bench coagulation tests as a further post-treatment.

    Treatment line

    1. 01Ammonia strippingPreliminary step for partial removal of ammoniacal nitrogen.
    2. 02Activated sludge in sequential batchesNitrification and denitrification by the short nitrite route to remove the nitrogen series.

    What the source found

    The line removed 97% of ammoniacal nitrogen and 70% of nitrate, and also 50% of true colour, 31% of COD, 45% of BOD and 56% of dissolved organic carbon. The COD and BOD left were still above the state limit and the colour stayed high, so a further physico-chemical treatment was needed before discharge.

    Two batches produced from September to November 2015, with the raw leachate characterised once and the treated leachate characterised at the start and end of the later tests and averaged.

    Water in, water out

    ParameterSymbolUnitInletOutletRemoval
    pH8.378.84
    AlkalinityAlkmg CaCO3/L3,9892,037
    Temperature°C2727
    Apparent colouruH5,4062,28858%
    True colouruH4,1092,05150%
    CODCODmg/L1,4751,01531%
    Dissolved organic carbonDOCmg/L270120
    BODBODmg/L25514145%
    Total Kjeldahl nitrogenTKNmg N-NH3/L4671597%
    Ammonia nitrogenNH3-Nmg N-NH3/L3441097%
    Nitrite nitrogenNO2-Nmg N-NO2/L6.6185%
    Nitrate nitrogenNO3-Nmg N-NO3/L1143470%
    ChlorideCl−mg/L2,1022,306
    Total solidsTSmg/L7,6128,015
    Total suspended solidsTSSmg/L23897
    Total dissolved solidsTDSmg/L7,3747,918

    Inlet: raw landfill leachate. Outlet: leachate after ammonia stripping and activated sludge in sequential batches. Raw leachate characterised once; treated values are the mean of the start and end characterisations of the treated batch, 2015. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.

    Similar references