COD and BOD removal from canned food factory wastewater by separator and anaerobic tanks
A factory in the Yogyakarta Special Region makes canned gudeg for domestic and export markets, and its wastewater is raw material wash water and cooking water from batch production. The treatment unit has an initial capacity of 2.64 m³/day and receives about 1.58 m³/day; its effluent goes to a river and was failing the regional discharge standard, so the unit was evaluated and improvements were proposed.
Treatment line
- 01ScreeningScreen plate meant to hold back rubbish and solids larger than 4 mm, but undersized for its channel so solids pass beside it.
- 02Separator tankCovered tank where solids float or settle by density and decomposing bacteria are added; scum builds up and is not cleaned.
- 03Series of anaerobic tanksCovered suspended-growth anaerobic tanks with added bacteria in the second compartment.
- 04Two control tanksCovered tanks of different sizes before discharge to the river.
What the source found
The unit removed 87% of BOD, 93% of COD and 72% of suspended solids. Suspended solids met the regional standard, but BOD and COD did not, and the effluent was too acidic. Causes found were an undersized screen, uncleaned scum that soured the water, an organic load above what the anaerobic tanks can handle, bacteria unsuited to anaerobic treatment, and no neutralisation. Proposed improvements were a correctly sized screen, scum cleaning and coagulant in the separator, replacing the anaerobic tanks with an anaerobic biofilter on plastic ball media, anaerobic bacteria, and lime neutralisation with open control tanks.
Four sampling rounds over two weeks, each at the end of a production batch, with a time composite at the inlet before the screen and a grab sample at the outlet before the river; results were averaged.
Water in, water out
| Parameter | Symbol | Unit | Inlet | Outlet | Removal |
|---|---|---|---|---|---|
| pH | 6 | 4.75 | |||
| BOD5 | BOD5 | mg/L | 2,908.75 | 379.25 | 87% |
| COD | COD | mg/L | 11,418.75 | 834.38 | 93% |
| Total suspended solids | TSS | mg/L | 502.5 | 142.75 | 72% |
| Temperature | °C | 29.5 | 29.63 |
Inlet: raw wastewater at the plant inlet before the screen. Outlet: final effluent before discharge. Means of four sampling rounds over two weeks. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.