Aguato

    COD removal from fish processing wastewater by a compartmented anaerobic reactor and filter

    A tilapia processing plant in southern Minas Gerais, which covers the whole chain from breeding to rearing in net cages in a reservoir, treats all of its processing wastewater before releasing it to that reservoir. The treatment plant was designed for six tonnes of fish a day.

    Treatment line

    1. 01Static screenReceives the wastewater by gravity through a pipe.
    2. 02Grease removal device2.9 m³ useful volume.
    3. 03Equalisation tank54.7 m³ useful volume.
    4. 04Compartmented anaerobic reactor100.8 m³ reactor with upflow through sludge blankets in several chambers, 2.2 days retention, seeded with sludge from an earlier upflow anaerobic reactor at the site.
    5. 05Anaerobic filter50.9 m³ useful volume, 1.1 days retention, as post-treatment.

    What the source found

    The whole line removed 74% of total COD, 73% of BOD and 48% of suspended solids on average, with most of the COD removed in the compartmented reactor. COD removal met the state rule for discharge, while BOD removal fell just short of it. The screen let sludge through and the grease removal device released settled material, so it often added solids and organic matter instead of removing them, and the plant ran at about 20 °C, below the best range for anaerobic digestion.

    Fortnightly samples at the inlet and outlet of the screen, the grease removal device, the anaerobic reactor and the anaerobic filter, with temperature read daily.

    Water in, water out

    ParameterSymbolUnitInletOutletRemoval
    BODBODmg/L65816974%
    Total CODCODmg/L1,715371
    Filtered CODsCODmg/L324193
    Particulate CODmg/L1,515234
    Total suspended solidsTSSmg/L388102
    Volatile suspended solidsVSSmg/L382100
    pH5.966.36
    Total alkalinityAlkmg/L91242
    Volatile fatty acidsVFAmg/L18885
    Intermediate to partial alkalinity ratio2.311.06

    Inlet: raw processing wastewater entering the screen. Outlet: outlet of the anaerobic filter. Means of fortnightly samples over the monitoring period. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.

    Similar references