Phosphate and ammonium recovery from fertilizer wastewater by struvite crystallization
Wastewater rich in phosphate and ammonium was taken from the treatment plant of a fertilizer factory, where it passes an equalization tank and a settling pond, and treated in a laboratory reactor. The aim was to recover the two nutrients as struvite, a slow-release fertilizer, instead of letting them cause eutrophication.
Treatment line
- 01Wastewater tank with acidity adjustmentCaustic soda or sulfuric acid is added to bring the wastewater to the alkaline range that suits struvite formation; recirculated effluent returns here.
- 02Fluidized bed crystallization reactorA column 1.5 m high and 5 cm wide, fed with the wastewater and a magnesium chloride solution, with the effluent recirculated 3, 6 or 9 times.
- 03Crystal catcherA wider top section 0.25 m high that keeps crystals from leaving with the treated water.
What the source found
The best setting, nine recirculations at the lowest loading rate, recovered 56% of the phosphate and 50% of the ammonium and removed 24% of suspended solids. More recirculation and longer detention in the reactor improved recovery, and most of the crystals formed at the best setting were struvite. Fluoride and other impurity ions in this wastewater interfered with the crystals, so pretreatment to remove them is advised.
A 105 L composite of samples taken three times in one day at the factory treatment plant was run through the reactor at three recirculation ratios and three loading rates, with the outlet sampled at each recirculation pass.
Water in, water out
| Parameter | Symbol | Unit | Inlet | Outlet | Removal |
|---|---|---|---|---|---|
| pH | 8.63 | ||||
| Magnesium | Mg | mg/L | 312.9 | ||
| Phosphate | PO43− | mg/L | 1,800 | 56% | |
| Ammonium | NH4+ | mg/L | 1,710 | 50% | |
| Fluoride | F− | mg/L | 122 | ||
| Total suspended solids | TSS | mg/L | 122.02 | 92.98 | 24% |
| COD | COD | mg/L | 72 | ||
| Silica | SiO2 | mg/L | 850 | ||
| Calcium | Ca | mg/L | 101.2 |
Inlet: composite fertilizer wastewater fed to the crystallization reactor. Outlet: reactor effluent after the recirculation passes. One laboratory run of a 105 L composite sample at a recirculation ratio of 9 and 0.39 L/min. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.