Aguato

    Solids and COD removal from ceramic-tile wastewater by coagulation with polymer flocculants

    A ceramic-tile factory in Yazd, Iran, produces production-line wastewater that is very high in suspended solids and turbidity. Settling alone gives water fit only for the slurry section, so jar tests looked for a coagulation and flocculation treatment good enough for reuse elsewhere in production, and compared its cost.

    Treatment line

    1. 01Primary settlingAbout 100 minutes of settling before any chemical was added.
    2. 02Acidity adjustmentLime or hydrochloric acid to bring the water to the neutral optimum found in the tests.
    3. 03Coagulation with poly-aluminium chloridePoly-aluminium chloride as coagulant, its dose cut when a polymer aid was added.
    4. 04Flocculation with polymer aidsAnionic, cationic or non-ionic polymers, alone or in pairs, to build larger flocs before settling.

    What the source found

    Poly-aluminium chloride with an anionic plus non-ionic polymer pair worked best, removing above 99% of suspended solids, 88% of COD and 95% of colour, with the anionic polymer on its own close behind and far more COD and colour removed than with the coagulant alone. The polymer aids lowered the coagulant dose and made treatment of each cubic metre cheaper than using the coagulant alone; zinc, chromium and cadmium were also largely removed, boron less so.

    Jar tests in triplicate at 25 °C on composite samples of the factory's production-line wastewater taken across working shifts, testing settling time, pH, coagulant dose and polymer type and dose.

    Water in, water out

    ParameterSymbolUnitInletOutletRemoval
    pH8.3
    Temperature°C31
    Electrical conductivityECμs/cm2,484
    TurbidityNTU11,10099.9%
    Total dissolved solidsTDSmg/L1,192
    Total suspended solidsTSSmg/L21,63899.9%
    CODCODmg/L361.335788%
    BOD5BOD5mg/L266.5167
    Colour94%
    CadmiumCd91%
    ChromiumCr94%
    NickelNi76%
    ZincZn96%
    LeadPb76%
    BoronB54%

    Inlet: raw production-line wastewater. Outlet: supernatant after coagulation with PAC and anionic plus non-ionic polymers. Inlet means of composite samples; removals from triplicate jar tests at the best polymer pair. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.