COD and nitrogen removal from shrimp farm wastewater by growing a salt-tolerant microalga
Wastewater discharged from biofloc shrimp culture units at a university research station in Sisal, Yucatán, was taken to the laboratory. The water is low in nitrogen and high in organic matter, and the aim was to clean it while growing algal biomass rich in lipids and fatty acids.
Treatment line
- 01AutoclavingThe raw wastewater was sterilised before inoculation so that only the alga acted on it.
- 02Aerated microalga culture flasks1 litre flasks inoculated with the microalga, aerated continuously at 24 °C under constant light.
What the source found
In undiluted wastewater the alga removed 80% of COD, 82% of total ammonia nitrogen and 76% of total nitrogen. The undiluted water gave the best algal growth of the wastewater treatments, though growth stayed well below that in the reference medium.
Triplicate 1 litre flask cultures of undiluted wastewater and two seawater dilutions, compared with a reference culture medium, with pollutants measured every 48 hours.
Water in, water out
| Parameter | Symbol | Unit | Inlet | Outlet | Removal |
|---|---|---|---|---|---|
| pH | 7.4 | ||||
| Salinity | psu | 36 | |||
| Total nitrogen | TN | mg/L | 3.1 | 76% | |
| Nitrate | NO3− | mg/L | 1.69 | 85% | |
| Nitrite | NO2− | mg/L | 0.63 | 46% | |
| Total ammonia nitrogen | NH3-N | mg/L | 0.81 | 82% | |
| Phosphate | PO43− | mg/L | undetectable | ||
| COD | COD | mg O2/L | 458.1 | 80% |
Inlet: raw shrimp farm wastewater, undiluted. Outlet: culture water at the end of the microalga batch. Triplicate flask cultures of undiluted wastewater; inlet characterised once, removals are the source's own percentages. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.