Aguato

    Desalting power plant wastewater for reuse by membrane capacitive deionization

    Real mixed wastewater from a combined cycle power plant in Korea, made up of power generation, washing and cooling wastewater, was tested for reclamation as plant make-up water instead of discharge. Two samples were used: a high-salinity one as the worst case, for finding the best settings, and a less salty one for a longer run.

    Treatment line

    1. 01Membrane capacitive deionization cellA bench cell of activated carbon electrodes, each 100 by 100 mm, faced with cation and anion exchange membranes, removing salts while charged and releasing them as a concentrate on reversal; best run at 1.5 V and 15 mL/min with a desorption time of 0.8 times the adsorption time.

    What the source found

    At the best settings the cell removed 86% of dissolved solids, which was judged enough for industrial reuse. Over 10 days of continuous operation salt removal fell from 94% to 56% as calcium and magnesium scale with silica and organic matter built up on the cathode, membranes and spacers. Cleaning with dilute acid and then dilute caustic, started once removal had dropped below 70%, brought it back to about 93%.

    Twenty-one short runs set by a response surface design to find the best voltage, flow and cycle timing, one analysed run at those settings on the high-salinity sample, and a 10 day continuous run on the less salty sample to study fouling.

    Water in, water out

    ParameterSymbolUnitInletOutletRemoval
    pH8.297.1
    Electrical conductivityECμS/cm2,402329
    Total organic carbonTOCmg/L3.21.553%
    ChlorideCl−mg/L14513.891%
    Alkalinity as CaCO3Alkmg/L1057
    Hardness as CaCO3THmg/L2673786%
    TurbidityNTU0.120.230%
    IronFemg/L0.0170.0190%
    AmmoniumNH4+mg/L0.030.0167%
    SulfateSO42−mg/L857.791%
    Total dissolved solidsTDS86%

    Inlet: high-salinity mixed power plant wastewater fed to the cell. Outlet: product water of the capacitive deionization cell. One run at the optimum settings on the high-salinity sample. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair. A parameter at 0% did not fall between the inlet and the outlet.