Aguato

    COD and toxicity removal from coal gasification wastewater by a constructed wetland

    The wastewater came from the gas scrubber of an ex-situ underground coal gasification test rig at an experimental mine in Mikołów, Poland, and was strongly acidic and loaded with phenols, aromatic hydrocarbons, cyanide, ammonia and metals. Three wetland columns were run side by side with a control. The one described here was fed with wastewater from the test in which coal was gasified with oxygen.

    Treatment line

    1. 01Feed tank with recirculationA 70 litre tank beside the column held the raw wastewater, which was pumped through the column and back while being mixed.
    2. 02Vertical subsurface flow constructed wetland columnA 0.3 m wide, 0.8 m tall column of compost over sand and two gravel layers, planted with eight common reed cuttings, with a flow of about 5.65 litres per day and a 2 day retention time.

    What the source found

    Over 60 days the wetland removed 93% of COD and 98% of BOD, and phenols, aromatic hydrocarbons and cyanide almost completely, together with most chromium, nickel and iron. Ammonia, total nitrogen and chloride fell only partly, manganese rose, and calcium and magnesium leached from the gravel. The acute toxicity of the effluent fell from very high to low or none by the end of the 150 day run.

    Raw wastewater was analysed at the start and the column effluent after 14 and 60 days, with toxicity tests on the effluent up to 150 days.

    Water in, water out

    ParameterSymbolUnitInletOutletRemoval
    pH1.86.4
    Electrical conductivityECmS cm-18,6403,300
    Redox potentialORPmV382259
    Ammonium (NH4)NH4+mg L-11609839%
    Nitrate nitrogenNO3-Nmg L-10.12<0.1017%
    Nitrite nitrogenNO2-Nmg L-1<0.0020.011
    Total nitrogenTNmg L-11208232%
    BODBODmgO2 L-1550998%
    CODCODmgO2 L-11,0607293%
    Total organic carbonTOCmgC L-13502693%
    ChlorideCl−mg L-11,1201,0803.6%
    SulfateSO42−mg L-1106<1091%
    NitrateNO3−mg L-10.53<0.505.7%
    NitriteNO2−mg L-1<0.0060.036
    Total cyanideCN−mg L-142<0.002>99.9%
    Phenol indexmg L-11650.0091>99.9%
    Total phosphorusTPmg L-10.1<0.06535%
    SulfideS2−mg L-10.25<0.02
    IronFemg L-122.70.2299.0%
    ManganeseMnmg L-10.391.77
    AntimonySbmg L-1<0.05<0.05
    ArsenicAsmg L-1<0.05<0.05
    BoronBmg L-11.751.4915%
    Total chromiumCrmg L-14.830.005899.9%
    ZincZnmg L-14.65<0.0599%
    AluminiumAlmg L-13.020.1794%
    CalciumCamg L-11.34397
    CadmiumCdmg L-10.0084<0.00188%
    CobaltComg L-10.0710.005293%
    CopperCumg L-1<0.01<0.010%
    MagnesiumMgmg L-10.3925.6
    MolybdenumMomg L-1<0.005<0.0050%
    NickelNimg L-12.210.04498%
    LeadPbmg L-13.06<0.0299.3%
    MercuryHgmg L-1<0.001<0.001
    SeleniumSemg L-1<0.05<0.05
    TitaniumTimg L-10.0690.00593%
    Polycyclic aromatic hydrocarbonsμg L-11,7315.599.7%
    BTEXμg L-1732<0.499.9%
    Acute toxicityTU405.42.0999.5%

    Inlet: raw gasification wastewater at the start of the run (day 0). Outlet: wetland column effluent after 60 days. Means of three determinations for wetland column 2 at day 0 and day 60. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair. A parameter at 0% did not fall between the inlet and the outlet.