COD and suspended solids removal from paint factory wastewater by settling and aerated filters
An underground treatment plant at a water-based paint factory in Alexandria treats wastewater mainly from vessel and floor cleaning, rich in suspended solids, pigment colour and oil and grease. The flow ranges from 50 to 120 m³/day, with an average of 70 m³/day. The treated water has to meet the national law for discharging industrial wastewater to the sewer system.
Treatment line
- 01Aerated primary sedimentation tankSix hours of retention with a water barrier in the middle; air is supplied to keep the water aerobic.
- 02Aerated gravel filterBiological aerated filter on gravel, 2.2 m high, 2 m wide and 2 m long.
- 03Aerated anthracite and sand filterSame size as the gravel filter, packed with anthracite and sand at 3 to 1 by volume.
- 04Secondary sedimentation tankSame size as the primary tank; settled sludge is pumped monthly to a drying lagoon.
What the source found
Over the whole line COD fell by 96%, BOD by 93% and suspended solids by 98%, and the effluent met the national limits for discharge to the sewer without any chemical dosing. Primary settling alone removed most of the suspended solids and was the limiting step, and the visible colour disappeared after the anthracite and sand filter.
Composite samples over the 8 working hours at five points along the line during six months, February to July 2007.
Water in, water out
| Parameter | Symbol | Unit | Inlet | Outlet | Removal |
|---|---|---|---|---|---|
| pH | 8.73 | 7.88 | |||
| COD | COD | mg/l | 1,711 | 66.92 | 96% |
| BOD5 | BOD5 | mg/l | 748 | 50.4 | 93% |
| Total suspended solids | TSS | mg/l | 3,821 | 91.17 | 98% |
| Total viable count | cfu/ml | 848,750 | 1,495 | 99.8% | |
| Total coliform | TC | cfu/100ml | 64,125 | 10,673 | 83% |
| Faecal coliform | FC | cfu/100ml | 29,210 | 98.5 | 99.7% |
Inlet: raw wastewater entering the treatment plant. Outlet: final effluent after secondary sedimentation. Averages of composite samples over the 8 working hours from February to July 2007. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.