Aguato

    Recycling concrete plant wash water by settling, oil separation and CO2 neutralisation

    A concrete mixing plant making admixture-rich concrete produces alkaline wash water from cleaning its equipment and truck mixers, carrying fine cement particles, admixtures, oils and salts. The plant installed its treatment system because the water could not be discharged untreated, and the treated water is considered suitable for reuse in concrete. The wash water first passes two settling tanks that remove gravel and sand; the section described here runs from the second settling tank to the treated water.

    Treatment line

    1. 01Third settling basinLast of three cascade settling basins that remove solid particles.
    2. 02Oil and hydrocarbon separatorRemoves oils, fuels and other immiscible substances from equipment and admixtures.
    3. 03Carbon dioxide injectionPartly neutralises the alkalinity and stabilises the water before reuse.

    What the source found

    From the second settling tank to the treated water, suspended solids fell by 97% and the water came close to drinking water in pH, suspended solids and mineral ions, but dissolved salts such as chloride and sulfate largely remained. Mortars made with the treated water were more porous, shrank more and were weaker than mortars made with drinking water, and the effect was stronger than with the partly settled water.

    Laboratory analysis of water taken from the second settling tank and of the fully treated water, followed by mortar tests in which these waters replaced drinking water in steps up to full replacement.

    Water in, water out

    ParameterSymbolUnitInletOutletRemoval
    Suspended solidsTSSmg/L3,4009397%
    pH10.97.5
    ChlorideCl−mg/L8050
    SulfateSO42−mg/L9060
    Sodium as Na2ONa2Omg/L252020%
    Potassium as K2OK2Omg/L106.535%
    PhosphatePO43−mg/L0.050.0420%
    NitrateNO3−mg/L604033%
    Total sugarsmg/L20012040%
    LeadPbmg/L0.020.01
    ZincZnmg/L0.30.233%
    Dissolved saltsmg/L1,500900
    Hexavalent chromiumCr(VI)mg/L0.02<0.01
    Hydrocarbon indexmg/L50.5

    Inlet: water from the second settling tank. Outlet: recycled water after the full treatment line. One analysis of each water, no sampling details given. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.